S2000

The OmniCure S2000 is engineered for high-speed automated manufacturing assembly. Building on the core OmniCure technology found in the OmniCure S1000, the OmniCure S2000 has a more powerful 200 Watt lamp with a 2000 hour life guarantee.

The OmniCure S2000 also offers Closed-Loop Feedback, and the added flexibility of a PC software interface for computer-controlled operation. More robust and with enhanced reliability, the OmniCure S2000 raises the bar for mission critical bonding applications. Designed to adhere to regulatory validations and is RoHS compliant.

Faster Shutter Activation
The OmniCure S2000 is equipped with a faster shutter activation time, providing a maximum trigger shutter activation latency of only 50ms in PLC mode.

Downloadable StepCure
StepCure software has the option to download a customized multi-phase cure profile directly to the system. Previously only available while connected to an external Desktop PC, this offers users more convenience and greater efficiencies.

200 Watt Intelli-Lamp
The powerful 200 Watt Intelli-Lamp, with a guaranteed life of 2000 hours, provides even faster curing with high UVA irradiance of up to 10W/cm2.

Multiple Site Light Delivery
The OmniCure S2000 is ideal for use with multi-legged High Power Fiber Light Guides to cure multiple sites with a single light source. Also offered are Single-Legged, Liquid-Filled or Fiber Light Guides to suit most customer needs.

Intelligent Automation
The OmniCure S2000 is ideal for automated processes, and is easily integrated into an automated system, minimizing development time. The curing system can be programmed and controlled externally from a PLC, with or without an external dongle, using the 15-pin I/O ports or directly from a PC via serial communication. PC software and commands are included with the system.

Patented Closed-Loop Feedback
Automatic Correction to Lamp Intensity Drop-off 

Over time, lamp intensity diminishes effective curing.

The OmniCure S2000 internal intensity sensor monitors light output in real time, and opens the iris to automatically correct light output within +/-5%, ensuring repeatable and measurable doses of energy leading to increased yields and quality.

OmniCure Closed-Loop Feedback
A PLC/audible alarm warns when the lamp can no longer generate the set irradiance level. Now you can use your lamp until the end of its lifetime, without the requirement to check for lamp intensity.

Calibration with the OmniCure R2000 Radiometer offers real time display of irradiance on the OmniCure S2000.

  • The only system that can be calibrated in real time for NIST accuracy
  • Ideal for automated or semi-automated environments
  • Often imitated – never duplicated
S2000 Spot Curing
Closed-Loop Feedback
Closed-Loop Feedback

OmniCure S2000 Typical Irradiance*
(W/cm2), 5mm LG & 0mm Working Distance

S2000R2000 
Filter (nm) Irradiance (W/cm2)
320-50024.70
400-50016.55
320-3909.83
3657.28
250-45026.64
no filter37.333